- 钢丝拉力试验机
- 钢丝拉力试验机
钢丝拉力试验机
示值无规律的偏差
Eight, showing the value of deviation is irregular
齿杆、齿轮有油污、磨损或有毛刺:消除齿杆、齿轮的油污、毛刺,找出超差时的齿杆接触点,然后修正齿杆、齿轮;如不能消除误差.更换齿杆、齿轮。
rack, gear oil, abrasion or burr: eliminate the rack, gear oil, burr, find out the pole difference when the contact points, and then modified tooth bar, gear; if not eliminate errors. Replace the tooth bar, gear.
拉力试验机试验机安装不水平:调整水平。
tensile testing machine testing machine installation is not level: level adjustment.
齿杆弯曲:校直或更换齿杆,调整滚动槽轮的问隙。
toothed bar bending: alignment or replacement tooth bar, adjust the roll gap groove wheel.
钢丝拉力试验机计算机软件联机后出现提示框信息显示超载。
Nine, computer software on-line prompt box display information overload.
解决方案是检查计算机与试验机的通讯线是否脱落;检查联机选择传感器是否选择正确;检查近的试验或操作键
The solution is to check the computer and test machine communication line is off; check the online selection of sensor is correct; check the last test or operation keys
盘时传感器是否被撞过;检查出现问题之前是否使用了软件的校准或标定功能;检查是否手动更改过校准值、标定值或硬件参数中的其他信息。
When the sensor is knocked off; check whether the use of a software appears calibration or calibration before; check whether the manual modified calibration values, calibration information value or other hardware parameters in the.
试验机主机电源不亮,不能上下移动。
Host ten, the power of the testing machine does not light, not to move up and down.
解决方案是检查接入试验机的电源线路是否连接正常;检查急停开关是否处于拧起状态;检查接入试验机的电源电压是否正常;检查机器插座上的保险是否烧断,请取出备用保险丝安装即可。
The solution is power line inspection access testing machine is connected properly; check the emergency stop switch is in screwed up state; power supply voltage check access testing machine is normal; check the socket on the insurance is burned off, remove the spare fuse can be installed.
试验机主机电源有电但设备不可以上下移动。
Host eleven, testing machine power supply with power but the equipment can not move up and down.
解决方案是检查是否是15S(时间)以后设备还无法移动,因为主机开机需要自检,大概需要15S时间;检查上下限位是否再恰当的位置,有一定的运行空间;检查接入试验机的电源电压是否正常。
The solution is to check whether it is 15S (time) after the device is unable to move, because the host boot take self-inspection, probably need 15S time; check the upper and lower limit is again appropriate position, operating space; check supply voltage access testing machine is normal.
油源的保养:
Eight, oil source:
定期检查主机和油源处是否有漏油的地方,如发现有漏油,应及时更换密封圈或组合垫;
regularly check the host and the supply of oil leaks place, if there is oil leakage, should be promptly replaced seal ring or a combined pad;
根据机器的使用情况及油的使用期限,定期更换吸油过滤器和滤芯,更换液压油。
according to the use condition and oil machine use period, replace the oil filter and filter periodically, replacing the hydraulic oil.
长时间不做试验时,注意关断主机电源。如果机器在待机状态,转换开关应打到“加载”档,因为如果转换开关打在“快退”档,电磁换向阀一直在通电状态,会影响 该器件的使用寿命。
Experiment 3, not long time, pay attention to shut off the main power. If the machine is in the standby state, the switch should call the "load" file, because if the switch on the "rewind" file, electromagnetic reversing valve has been in a power-on state, affect the service life of the device.
控制系统保养:
Nine, control system maintenance:
定期检查控制器后面板的连接线是否接触良好,如有松动,应及时紧固;
regularly check the controller panel connecting line is good contact, such as loose, should be timely fastening;
试验后若有一段较长的时间不用机器时,关闭控制器和电脑;
after the test if there is a long time not machine closed, controller and computer;
控制器上的接口为一一对应,插错接口可能对设备造成损坏;
the controller interface for the corresponding one one, inserted the wrong interface may cause damage to the equipment;
插拔控制器上的接口必须关闭控制器电源。
Swap Controller Interface must be shut down the power supply controller.